Introduction
As the S/390* transformation from its legacy of large, complex,
bipolar-based mainframes to simpler, CMOS-microprocessor-based servers
continues, increasingemphasis is being placed on the system
structure and memory hierarchy. As described by
Getzlaff et al. [1], the S/390 Parallel
Enterprise Server
Generation 3 (G3) features a system structure which supports
microprocessor and system frequencies in excess of 160 MHz. This design
features conventional, dedicated L1 and L2 caches as well as a novel,
shared L2.5 cache [2] which services all
of the microprocessors in
the system. This topology provides impressive system-level performance
and has excellent scaling capabilities.
However, the introduction of the S/390 G4 microprocessor
[3], with
its design goal of doubling the microprocessor frequency, was expected
to increase memory subsystem performance requirements. The L2 cache
design team was challenged to provide the means to enable the
introduction of this new microprocessor while reusing as many S/390 G3
components as possible. The first challenge involved system cycle time.
Because of the desire to reuse the S/390 G3 memory hierarchy,
speed matching between the new, faster S/390 G4 microprocessor and the
reused components would be needed. Second, the utilization level of the
system bus was observed to be increasing rapidly with increasing
microprocessor frequency. Doubling the microprocessor speed was likely
to cause considerable acceleration of this effect, thereby
necessitating a mechanism for reducing bus traffic. Third, analysis of
typical S/390 workloads indicated that there was a large degree of
sharing of instructions and data among the processing elements of an
S/390 system. It would thus be very advantageous to introduce a
shared-cache structure to the cache hierarchy. Finally, during the
design of the S/390 G3 system, it became apparent that a large
symmetric multiprocessor introduced unwanted packaging complexity on
the bus connections among the various system components. This last
challenge was solved on the S/390 G3 system by distributing four
microprocessors' private L2s across four SRAM cache chips
[1].
A number of alternative designs were considered for the S/390 G4 L2
cache. The initial desire was to introduce a large, fully shared cache
such as those found in bipolar ES/9000* SMPs. While this would
certainly have provided optimal system-level performance via higher
cache efficiency, this design approach was inconsistent with the
existing system bus design. In particular, the S/390 G3 memory
interface would have required a complete redesign to accommodate a
fully shared L2 cache. Performance analysis, however, indicated that
introducing cache sharing on each of the existing BSN system buses
would generate a large percentage of the advantage of shared caches
while also reducing system bus traffic. This scheme does not disrupt
the system design and bus protocols. The S/390 design team therefore
developed a hybrid solution consisting of fully shared three-way cache
clusters which attach to the existing S/390 G3 system bus
[4].
This L2 cache design resulted in an amount of aggregate L2 equivalent
to that available in the S/390 G3 (3 MB of total L2 capacity) while
reducing the L2 chip count by 33%. The value of shared caching was
confirmed by performance measurements which showed that the shared
caches improved cache hit rates by 40-50% over the predecessor
system. The cross-point switches introduced at the CP interface
maximize CP performance and minimize overall latencies, yet the system
bus interface was also maintained, enabling component reuse. Finally,
despite the fact that a shared-cache design is inherently more complex
than private L2s, the entire design cycle, from design concept through
initial product prototype, required only 15 months. Initial versions of
the S/390 G4 L2 chip were fully functional and exceeded frequency
goals; virtually the entire manufactured chip distribution operates at
or better than 200 MHz in CMOS 5X, making this a very high-yield,
low-cost, high-performance L2 cache chip.
The S/390 Parallel Enterprise Server Generation 4 memory hierarchy is
depicted in Figure 1. Each
microprocessor, or CP, contains 64 KB of store-through L1 cache. The L2
cache contains 768 KB distributed in a clustered configuration across a
pair of chips. An L2 cluster supports up to three CPs and provides
access to the entire memory space. The L2 cache chip provides the
speed-matching function required by the S/390 G4 CP, allowing the CP to
run at twice the frequency of the remainder of the system. This enables
the reuse of the S/390 G3 memory hierarchy (BSN, STC, etc.).
Figure 1
This paper discusses the operation and design of the shared-cache
clusters found in the S/390 G4 system¹;
it is divided into four main sections. The design and layout of the
S/390 G4 L2 cache are first described, with particular attention to
design challenges unique to a shared structure. The next section
addresses cache coherency issues unique to a shared-cache environment,
and the solutions devised to address them. The third section discusses
interlock controls in further detail. The paper concludes with a brief
summary of the key attributes of the S/390 G4 shared L2 cache.
L2 and L2 cache are used to refer to a single
chip in an S/390 G4 L2 cache cluster. When discussing operations which
span the pair of cache chips, the terms cluster or L2
cluster are used. The reader should also keep in mind that since a
cluster consists of two independent L2 cache chips, and there may be up
to four clusters in the current design point, up to eight
independent L2 cache chips may simultaneously be performing the bus
operations described here. Finally, the four clusters which
comprise a fully populated system all share the same common main memory.
Glossary of terms
BIDI: Bidirectional
BIF: BSN InterFace
BSN: Bus Switch Network--the chip which controls bus traffic in
S/390 G3 and G4 systems
BSNAR: BSN interface Address Register
BUSRR: BUS Request Register
CFAR: CP Fetch Address Register
CL: Changed Line bit--indicates that the data in the tagged line
have been altered and are therefore of more recent vintage than those
stored in main memory
CLST: Conditional Line STore
CP: Central Processor or Central microProcessor
CPAR: CP interface Address Register
CPID: Central Processor ID
doubleword: Eight bytes
L1: Level-1 cache
L2: Level-2 cache
LFAR/LFARA/LFARB: Line Fetch Address Register--register(s) used
to stage CP fetch requests
LSAR/LSARA/LSARB: Line Store Address Register--register(s) used
to stage store requests to main memory
LSLF: Line Store/Line Fetch operation--a fetch with an
accompanying cast-out
LRU: Least Recently Used--an algorithm for determining which
line(s) to replace with newer lines in the cache
MC: Multi-Copy bit
quadword: Sixteen bytes
RAS: Reliability,
Availability, Serviceability
SEC/DED: Single-Error
Correct/Double-Error Detect ECC code
SMP: Symmetrical MultiProcessor
XI: Cross-Invalidate--a mechanism to ensure cache coherency by
invalidating lines out of L1 and/or L2 caches
S/390 G4 shared L2 cache
The S/390 G4 shared L2 cache chip is an integrated design, with
both the large custom SRAM [5] and cache
controls contained on the
same chip. The shared cache consists of two identical chips, each
containing 384 KB of SRAM, for a total of 768 KB of cache per cluster.
The entire memory address space is mapped across this pair of L2 chips,
interleaved across the four memory cards to maximize concurrent
operation. The cache itself is six-way set-associative, is
dual-interleaved, and has directories dedicated to each system bus.
Each L2 chip features nonblocking switch functions to each attached CP
as well as to the other system components. Data buffers in the cache
array itself are also provided in order to minimize latency effects.
The result of the implementation of these design concepts is an L2
cache which enables concurrent execution of multiple requests, whether
from the CPs or from other L2 clusters.
To enable achievement of CP cycle-time objectives, the L1 cache was
designed as a store-through cache, meaning that altered data must also
be stored to the next-level cache. The L2 cache is a store-in design,
which helps to control and minimize system bus activity. A full subset
cache protocol is used to manage data coherency between the L1s and
L2s; this means that all lines contained in any L1 are also stored in
that cluster's L2. The advantages of this scheme will become apparent
below.
In addition to performance, the S/390 G4 L2 cache provides
excellent RAS characteristics. This design contains SEC/DED ECC on both
the cache and directory arrays. Error correction in all cases is
provided "on the fly," with no additional access penalty.
When uncorrectable errors are encountered, system recovery actions are
triggered. The L2 cache and directory also support a "cache-line
delete" function [6] which allows removal
of a small number of
cache lines from active use to prevent known stuck faults from
becoming uncorrectable faults. Finally, in the S/390 G4 system, it is
possible for one or more individual CPs to halt because of error
without causing a system checkstop. Since cache coherency is managed by
the shared L2, failing CPs can be logically removed from the active
configuration with no data integrity exposure.
The high-level data and address flow of the S/390 G4 shared L2 cache is
depicted in Figure 2. This
shared L2 cache comprises the following critical component functions:
- L2 pipeline and arbitration unit, which provide the means
for controlling multiple requests for the shared L2 cache facilities.
- L2 directory, which maintains the contents of the L2 cache
array.
- CP interface controller, which provides fetch/store access to
the L2 from up to three CPs.
- BSN interface controller, which supplies the interface to the
other shared L2 clusters as well as to the shared L2.5 cache and main
memory.
- LSAR/LFAR controller, which stages and controls all fetch-miss
and write-back activity.
- Shared L2 cache array.
Figure 2
L2 pipeline
The L2 pipeline is shown in Figure 3.
All incoming requests processed
in the shared L2 cache must pass through the central pipeline. This
pipeline consists of a number of single-cycle staging registers that
perform different actions each cycle. A new request can be launched
into the pipeline every cycle; a request can take as few as two cycles
or as many as 11 cycles depending on its type and the availability of
the resources needed for completion.
Figure 3
A pipelined design was selected in order to effectively manage the high
level of activity from the L1 store-through traffic for the three CPs.
Stores can degrade performance when they are not drained fast enough,
thereby halting CP execution. To reduce the probability of creating a
bottleneck, the L2 has a pipeline design which can process a new
operation every cycle. The design also contains a store stack for each
CP that is deep enough to buffer the stores until they can be processed
through the pipe.
The central priority logic ultimately selects one requestor and gates
the corresponding requestor information (such as address, command,
mode, etc.) into the pipeline. A given requestor may make multiple
passes through the pipeline, performing different functions on each
pass. The action taken during each pipeline cycle depends on the
type and source of the command, and on the results of
previous passes through the pipeline.
- C1 cycle activities include
- Directory lookup and field update
- Command and address information sent to cache interleave
controls
- Address compares against internal resources and requestors
performed
- C2 cycle activities include
- Directory search results available
- First interleave busy cycle for a cache access operation
- LFAR facility selected on detection of L2 cache miss
- L2 cache request proceed/reject, based on the resource and conflict
resolution
- C3 cycle activities include
- LRU array access and/or update
- CL array access and/or update
- C4 cycle activities include
- First interleave busy cycle for a cache write operation
- Invalidate command sent to CP if the requested data have a coherency
conflict
- LSAR facility selected on L2 cache miss requiring a cast-out
- Completion response sent to CP if requested data hit in the L2 cache
with no coherency conflict
A cache read or write operation continues for several
additional cycles beyond C4 to complete the transfer of eight 16-byte
data shots.
Pipeline
arbitration
A total of 16 hardware requestors, dedicated for CP, BSN, and
internal L2 facility requests, can vie for priority to enter the
pipeline. Trying to route all 16 directly to some central arbitration
logic would have constituted a major physical wiring challenge.
Decentralizing the pipeline inputs by sending them through the
prepriority arbitration stations before forwarding to central priority
helped to prevent these potential wiring problems.
The prepriority arbiters funnel down the requests for central priority.
Each selects one of its requestors and then forwards the request to
central priority. At the same time, the prepriority arbiters forward
the corresponding requestor ID tag, address, command, mode, etc. buses
to the L2 pipeline. The prepriority arbiters also block requests whose
resource needs are not available (e.g., cache interleave conflicts),
and some arbiters equitably select requestors to avoid potential
processing lockouts. This particular lockout avoidance and others are
discussed in more detail in a later section.
There are a total of four prepriority stations within the L2 cache
chip. Each BSN port has a dedicated station, while the three CP ports
share the other two stations. A BSN prepriority station arbitrates
among the BSNAR, LFARB, and LSARA functions dedicated to the particular
BSN port. The selection is done in a priority order where BSNAR has the
highest priority, LFARB is second, and LSARA is last. BSNAR is picked
first because it reflects an XI (cross-invalidate) hit situation.
During the time it takes an L2 to resolve an XI hit, the BSN bus is
blocked from servicing a new operation. With bus utilization projected
to be relatively high, a reduction of utilization and, hence, queuing
was called for. LFARB and LSARA selection priority is not a critical
performance issue because of the low projected L2 miss rate.
Since each CP can have both fetch and store operations pending at any
point in time, two prepriority stations are supplied for the CP ports.
Because fetch operations are more critical to system performance than
stores, having separate arbiters for CP fetch and store operations
ensures that a fetch will always be selected over a store whenever both
operations are vying for priority concurrently. The CP fetch (or FAR)
prepriority station arbitrates among requests from the three CP ports
in a least-recently-processed scheme that avoids potential lockout. A
normal round-robin or a priority order chain scheme can cause a lockout
on a CP if there are sufficient activities from the other ports (such
as when CPs are in synchronous loops). The-least-recently processed
scheme is analogous to a least-recently-used (LRU) algorithm for
cache-line management, in which a most recent tag is updated whenever a
CP fetch (FAR) operation has completed processing in the L2. The
inverse of this tag determines which CP's request is the oldest,
thereby assigning it the highest priority in the FAR prepriority
station. Even though there are only three CP ports on the L2 chip,
there are a total of six request paths into this prepriority station,
two from each CP. One path comes from the chip interface register
called CPAR, and the other is from the CFAR hold register.
The prepriority station for arbitrating among the three CP store
requests employs a modified round-robin scheme to allow one of the
three store requestors to enter central priority
[7]. Stores are
checked for cache interleave conflict prior to arbitration in the
prepriority station to guarantee completion in a single pass through
the pipeline. Otherwise, pipe utilization would increase greatly
because of wasted pipeline passes. One undesirable side effect of this
greater pipeline efficiency is that some store requests can be locked
out indefinitely if higher-priority operations such as CP fetches
continue to keep the target cache interleave of the store operation
busy. The modified round-robin selection scheme guarantees that if the
highest-priority store request is not selected because of a cache
interleave conflict, and a lower-priority store requestor in the
round-robin is selected, the highest-priority store request will
prevail as the first store to be selected in subsequent cycles.
Normally in this situation, a regular round-robin would be updated and
a new store requestor would be given the highest priority in the
following cycle. However, in the modified scheme the round-robin is
updated only when a store requestor is selected, and no higher-priority
store requestors are blocked from priority because of cache interleave
conflict.
After the initial filtering at the four prepriority stations, the
surviving requestors meet in central priority for final selection into
the pipeline for processing. At this station, a straightforward
priority order chain selects the requestor. For reasons explained
above, requestors from the two BSN prepriority groups have the highest
priority, followed by the CP FAR prepriority group and finally by the
store prepriority group. A grant is not always given whenever there is
a pipeline request. Some of the reasons relate to actions taken as part
of recovery to prevent propagation of hardware faults and also to avoid
certain classes of lockout problems caused by allowing into the
pipeline requestors or operations that may inadvertently prevent
another requestor or operation from completing processing. Requestors
not granted pipeline access during the priority arbitration cycle
continue to request priority during each machine cycle until a grant is
received.
Directory
Each L2 chip contains two logical directories (or cache tag
arrays), one per BSN port. Each directory consists of 256 rows and is
six-way set-associative. With a 128-byte cache- line size, the
directory supports a total of 384 KB of L2 cache. A single logical
directory contains the following fields: address, CPID, changed line
(CL), and LRU. Physically, the address and CPID fields share the same
custom SRAM macro, which is accessed or updated in the C1 cycle of an
operation in the pipeline. The CL and LRU are contained in a shared
SRAM array macro that is accessed or updated in the C3 cycle of the
operation in the pipeline.
The address/CPID directory array may be accessed via the BIF register
during a snoop search or via the C1 stage of the pipeline during other
requests. The BIF register path to the directory is needed in order to
maintain bus protocol with the BSN for reporting a possible XI hit on a
bus snoop operation. Since there are two BSN ports on an L2 chip, the
directory is logically partitioned into two halves to support the
possibility of simultaneous directory lookups due to bus snoops on each
BSN bus. Snoop requests may be received from the BSN ports at any time;
when conflicts between snoops and other pipeline requests occur, the
snoop receives priority, and the internal request is recycled through
the pipeline once the snoop request has been satisfied.
The directory contains status information for data in the L2 cache, as
well as information on data ownership. A cache line can exist in four
possible ownership states: CP exclusive, CP read only with L2
exclusive, multiple copies in L2s, and invalid. This ownership
information is in the three-bit CPID tag field, where one of the bits
is the multiple copy (MC) tag bit.
The directory also maintains a changed line (CL) tag which tracks
whether a given line has been updated in the L2 cache by a CP store
operation or was brought into the L2 cache already in a changed state
from another L2 cache via a BSN bus operation. For a cast-out operation
(either LRU or XI), this information is used to determine whether the
copy of the line in this L2 cache is more recent than the copy in main
memory. If so, a memory update operation and/or XI cast-out operation
will result. Each directory entry has a CL bit. Normally, the CL bit is
set by a CP store operation in the C3 cycle of its pass through the
pipeline when it is known whether or not the operation has been
rejected.
An LRU array is also maintained for each congruence class (row) in the
directory. The partitioned LRU algorithm determines which of the six
compartments will be the one to be overwritten with new data when a new
line is being written into the cache for that congruence class. If
there are compartments which are not currently valid, one of these will
be chosen first. If all compartments are valid, the compartment pointed
to by the LRU code will be chosen. A partitioned LRU scheme was chosen
because it can support a CP store operation every cycle and its smaller
code field has a silicon area advantage over a true LRU algorithm,
which requires a longer LRU code field. Also, comparisons of the
partitioned and true LRU schemes have shown very little performance
difference.
CP controller
The CP controller is depicted in Figure 4.
The CP controller logic provides
the interface for up to three CPs, services all CP fetch and store
requests, and handles XI requests and responses from the other L2
clusters. The interface contains a fetch/store command bus, a
fetch/store address bus, a bidirectional fetch/store data bus, a fetch
response/data valid bus, store stack response signals, an XI command
bus, an XI address bus, and an XI response bus.
Figure 4
This interface was designed to handle one store request per system
cycle from each CP, and to optimize the data- return time for CP
fetches, while meeting the packaging constraints imposed by the chip
technology. Each CP has a dedicated interface, enabling each to
transmit fetch, store, and XI operations simultaneously and
independently of one another. The XI request controls are separate from
those for fetch and store operations, allowing XI requests to be
processed regardless of the fetch or store activity for a given CP.
Fetch and store commands are sent from the CP to the L2 via the command
and address buses. On store operations, up to one quadword of store
data is also sent with the command and address. The information is
captured in a CP interface register (the CPAR), and then routed to
either the fetch or store controls for further processing, allowing the
L2 to accept a new CP operation every cycle.
To optimize CP performance, fetch requests are given high priority and
may be routed to prepriority directly from the CPAR. This helps
minimize L2 latency on fetch requests. While only one outstanding fetch
request per CP is permitted, the L2 does allow the CP to present its
next fetch request once the data transfer for the initial request has
begun. This, too, is done to minimize storage latency effects.
There are three types of fetch requests:
- Read-only Typically, these are millicode or S/390
instructions. Read-only data may reside in the L1 caches of multiple
CPs.
- Exclusive A data line is requested in which one or more
bytes will be altered. A CP must have exclusive ownership of a line in
order to modify it.
- Conditional exclusive This request is usually for
operand information. The L2 may grant read-only or exclusive access,
depending upon the results of the coherency checking.
Store requests are gated into separate address and data store
stacks. The stacks are eight entries deep, allowing the L2 to accept up
to eight store requests from each CP. The stack queues the store
requests until L2 activity permits the processing of the next
sequential store request to the cache.
Since the CP normally owns the bus, each CP is allowed to continue
sending store requests unless or until data from a previous fetch
request are ready for transfer. When this occurs, the CP controller
issues a fetch alert response two cycles before the transfer is to
begin. This enables the CP to refrain from further store activity
and to switch the BIDI direction to receive the fetch data. Once
the data transfer is complete, the BIDI is switched back to its
default state, and store request activity can continue.
Cross-invalidate (XI) requests are sent to the CP by the L2 CP
controller when the status of a line held in the L1 must change. A line
may be invalidated if another CP submits an exclusive fetch request or
if the L2 must cast out the line. A line may also be demoted from
exclusive to read-only if another CP requests access to the line. An XI
request may originate from another CP within the cluster or from
another cluster.
Each L2 chip in the cluster can send a new XI request every cycle until
the XI stack within the CP is filled. It is the L2's responsibility to
track the number of pending XI requests and not overflow the XI stack.
As the CP processes the XI requests in FIFO order, it responds by
sending XI completion responses to the L2. Queueing the XI requests
within the CP helps optimize average XI latency by enabling a CP to
return an XI response every cycle.
Fetch requests
As stated previously, all requests for L2 access must be processed
through the L2 pipeline. As a selected fetch request is routed to
central priority, the fetch-request controls determine the availability
of the desired cache interleave. If an interleave conflict is detected,
no pipeline access is permitted in that cycle, effectively blocking
lower-priority requestors from "stealing" the pipeline from a fetch
request. The fetch request is granted pipeline access the following
cycle, and processing continues.
Fetch-request processing may be interrupted once in the pipeline. Each
time a fetch request makes a pass through the pipeline, prepriority and
central priority calculations are performed. Two mechanisms are used to
control the interruption and resumption of fetch requests. These are
the NEEDS and MODE registers.
Each CP interface contains a fetch NEEDS register. This register
contains an encoded value indicating the condition which must be
satisfied in order for the fetch request to resume processing. A NEEDS
value of all zeros indicates that all conditions are satisfied; any
nonzero value indicates the cause of the interrupted processing. Once
the required resource becomes available, the NEEDS register for that CP
is reset, and the fetch request is free to reenter prepriority for
pipeline access.
Each CP interface also has a MODE register. The MODE is used to
"remember" the results of the pipeline pass in progress so that the
subsequent passes will be processed more efficiently. For example,
checks which were successfully completed on an earlier pass for this
request need not be repeated. The NEEDS and MODE registers maximize
pipeline efficiency by preventing fetch requests from stalling the L2
pipeline.
To illustrate this concept with an example, suppose CP1 requests a line
of data that is currently held "exclusive"by CP2 (another CP on
the same cluster). On the first pipeline pass, an invalidate XI request
is sent to CP2. CP1's NEEDS is set to indicate that an XI response is
required before processing can continue. The MODE register indicates
that the request hit in the L2, but to a line owned exclusively by
another CP. When the XI response arrives, CP1's NEEDS is reset, and
the fetch request makes its second pass through the pipeline. The MODE
indicates that the line was held exclusive, so CP2's store stack must
now be checked to ensure that the latest copy of the line is
identified. If no store to this line is pending, the CP1 fetch request
obtains exclusive access to the line and the data are returned. If a
store to the requested line is pending, CP1's fetch request is again
interrupted, this time to allow the store to be processed. The NEEDS
register indicates waiting for stores, and MODE indicates store stack
compares detected. Once the cache has been updated with the latest
copy of the requested line, NEEDS is reset, and the final pass through
the pipeline completes as above [8].
Fetch requests are resolved in one of three scenarios:
- A fetch can complete in a single pipeline pass. This occurs
on requests which hit in the L2 with the requested line held exclusive
by the requesting CP; it also occurs on read-only and conditional
exclusive requests which hit CP read-only in the L2. The eight
requested quadwords are accessed by the cache controls and routed to
the CP BIDI data bus. The completion response is sent by the CP
controller with the first data transfer, indicating that a new CP fetch
request may be sent.
- A fetch request may make multiple pipeline passes in order to
generate local (within this cluster) XI requests. This scenario is in
effect if the fetch request hits in the L2 but the line is held
exclusive by another CP, or if the request was an exclusive fetch which
hits read-only in this L2 and the line is not resident in any other L2
cluster. For these cases, the fetch request makes multiple pipeline
passes to resolve the conflict(s) and to update the directory status.
On the final pipeline pass, data are returned, and the completion
response is sent to the CP.
- A fetch request results in a request sent on the BSN bus. There
are two scenarios in which this occurs. In the first, the request is an
exclusive fetch which hits read-only, and the line is in a
shared-ownership state where other clusters have copies of the line.
All of the copies in other clusters must be invalidated before the
current requestor can be granted exclusive access to the line. The
BUSRR sends an invalidate request to the remote L2 clusters via the BSN
bus and then notifies the requestor upon completion. Once invalidation
notification has been received, the requesting fetch is processed
through the pipeline as previously described. The second scenario is
the L2 miss. This results in an LFAR controller operation to request
data from the memory subsystem. In this case, data are returned from
one of three sources: main memory, the L2.5, or another L2 cluster.
Data are routed to the requestor CP immediately; the LFAR controller
then schedules the appropriate cache array update. This approach is
used to help minimize the overall L2 miss latency.
Store requests
Store requests from a given CP must be processed in FIFO order.
Stores from each of the three CPs compete for access to the pipeline in
the prepriority arbitration station. Unlike fetches, store interleave
conflicts are checked prior to prepriority. When a conflict is
detected, a lower-priority store from a different CP is allowed to
proceed. The round-robin algorithm is not updated, however. This allows
the first store to have the highest priority on the next cycle, when
the interleave conflict should be resolved.
Store requests from a specific CP must be processed in the order in
which they are received to ensure coherency. It is possible, however,
for a store request to enter prepriority to begin processing before the
previous store request from the same CP has completed. If this previous
store operation is interrupted, the later store request is also
interrupted. Processing on the second store resumes once the initial
store operation resumes.
Coherency rules dictate that a CP must have exclusive ownership of a
line in order to issue a store request. Therefore, the directory search
result must be "hit-exclusive" to the requesting CP. Any other
result, with one exception, is an error condition. The exception
involves a store request where the directory has not yet been validated
for a previous L2 fetch-miss operation (the line may be queued in the
LFAR, in the process of updating the cache). In this case, the store
request is allowed to continue once the cache and directory have been
updated.
BSN controller
There are two BSN controllers on each L2 chip, one dedicated to
each BSN port interface. Figure 5
depicts a single BSN controller.
Each BSN controller is divided into two subcontrollers which share a
common interface to the BSN bus. The BSNAR is responsible for all bus
snoop activity, while the BUSRR is responsible for all bus commands
initiated from within a shared L2 cluster. The BSN controller was
designed to allow the S/390 G4 L2 design to attach to the S/390 G3 BSN
bus, thereby enabling reuse of existing components. The BSN controller
therefore contains most of the critical function required to mate the
shared L2 cache cluster to the fully shared memory subsystem.
Figure 5
Each BSN port interface consists of a bidirectional bus (referred
to as the BSN bus) as well as several unidirectional control signals.
The BSN bus is used to transmit command, address, and data. Command and
address information is transmitted in the same cycle, while data are
sent in subsequent cycles. Because of relatively long memory DRAM
access times, the individual memory cards are organized into two
independent banks [1]. Consequently, the
BSN bus is logically
interleaved to take advantage of this, allowing two separate commands
to the memory subsystem to be active simultaneously on each bus
(meaning that there can be up to eight active memory operations across
the four BSNs in any cycle).
All four shared L2 clusters are considered logically to be connected to
the same BSN bus. However, physically there is a separate BSN bus for
each shared L2 cluster. When one L2 drives its BSN bus, the BSN chips
broadcast a copy on the BSN buses to the other shared L2 clusters on
the following system cycle.
Ownership of the BSN bus is established through a straightforward
handshake algorithm, using request, grant, and
command select control signals. In addition to these control
signals, the interface also includes transfer data signals
to indicate when data are being broadcast on the bus, memory
complete signals to indicate that a memory operation has
completed, and XI hit signals to indicate that there is an
XI address match on one of the other shared L2 clusters.
BUSRR
All commands destined for the BSN bus which originate in the L2
must pass through the BUSRR controller. The BUSRR register contains a
copy of the command and address waiting to be broadcast by this L2. It
must pass through the BIF register before being broadcast on the BSN
bus. Data to be stored or cast out of the cluster are held in the line
store buffer.
The BUSRR can receive command requests from three sources. These
sources are, in the priority order in which they are serviced:
- The pipeline (for example, because of special signaling
commands to the CPs).
- The LSAR controller (an LRU cast-out is required).
- The LFAR controller (a local CP fetch request results in an L2
cache miss, requiring a snoop to the other clusters).
When the BUSRR receives a command request, it attempts to gain
ownership of the BSN bus via a request signal. Upon
completion of BSN bus arbitration, the BSN bus BIDI is switched to
drive mode, and the command, address, and data (if any) are transmitted
in subsequent cycles. Once the command and address have been sent, the
command is transferred to the BUSRR-B register, freeing up the BUSRR
for the next command request. The BUSRR completes the command by
notifying the appropriate shared L2 controllers of operation
completion, generating encoded responses to be returned to the
requesting CP, and controlling the dataflow cross-point to route fetch
data to the correct destination.
To reduce L2 miss latency and better manage BSN bus and memory
utilization, two performance features have been added to the BUSRR for
those cases where a CP fetch misses in the L2 cache:
- The BUSRR monitors the pipeline in order to predict, up to
two cycles in advance, a new fetch request for data not held in the
local L2 cluster. If the BSN bus is not currently busy, the BUSRR
immediately issues a bus request. Command and address information are
then resolved in parallel with bus arbitration, enabling the new
request to be transmitted as soon as the bus is available.
- When fetch data must replace an existing cache entry, the line
being replaced must be written back to main memory if it has been
modified. Two mechanisms are available--LS/LF
[1], and conditional
line store (CLST)--for casting out the "old" line with minimal
performance impact. The method used is dependent upon the availability
of the data being stored relative to the completion of bus arbitration
for the fetch request. If the data to be stored are immediately
available, the LS/LF operation is used. If not (and this is the more
likely case, as an LRU operation may involve XI requests as well), the
fetch request is transmitted on the bus immediately. The CLST command
is then used to complete the operation, once the bus and the data to be
cast out are both available.
BSNAR
The BSNAR is responsible for processing commands originating in
the other shared L2 clusters. The incoming command and address are
received in the BSNAR via the BIF register, where a directory search is
immediately initiated to determine whether the requested data are
resident in the L2. If the directory search conflicts with an
operation currently in the pipeline, that operation is rejected and
scheduled for retry. The BIF-generated directory search must have the
highest pipeline priority because of a fixed-cycle relationship on the
BSN bus between the request and the activation of XI hit to
indicate that further action is required in the receiving L2 cluster.
In addition to the directory search, additional address compares are
performed against the LFAR and LSAR to determine whether the requested
data exist in a buffer. This protects data in transition to either the
L2 cache or the main memory. This address-compare function is discussed
in detail in a later section.
In the event of a directory hit or an LFAR/LSAR address compare match,
the XI hit signal is raised to notify the requesting cluster
that further action is required in the receiving cluster. At this
point, the BSNAR requests pipeline prepriority in a manner similar to
the other requestors. Like the CP controller, the BSNAR has NEEDS and
MODE registers which control and monitor progress through the pipeline.
The actions that must be performed by the BSNAR are dependent upon the
command and the status of the line in question. A whole range of
actions are possible, from doing nothing to initiating an XI cast-out
to a requesting L2 cluster, with corresponding invalidation of the
local cache entry. As an example, suppose the BSNAR receives a
fetch-exclusive request from another cluster and that the current
status of this requested line is exclusive to CPx,
changed, where x represents any one of the CPs in
the address-matched cluster. The BSNAR must
- Send an XI command to CPx requesting that CPx
invalidate its copy of the line.
- Wait for an XI response from CPx.
- Wait for possible outstanding store operations to the requested line by
CPx to complete.
- Access the L2 cache in order to read out the line while updating the
directory to invalidate this entry.
Once the line of data has been moved to the line store buffer, the
BSNAR must request the BUSRR to issue an XI cast-out with the
requested data. The usual handshaking protocols are not needed in this
case because the previously raised XI hit ensures that this cluster is
the current BSN bus master.
LFAR/LSAR
controller
The concept of data buffering has been around for some time; it is
an essential design technique for a high-performance multiprocessor
system [9]. The basic idea behind
buffering is to minimize latency
between cache and main storage and also to maximize cache utilization
by allowing concurrent cache operations during cache-miss situations.
In the application for the S/390 G4 L2, each BSN port contains a
line-fetch buffer and a line-store buffer; each buffer also has a pair
of associated address registers. The following is a description of
buffer- management techniques employed in the LFAR/LSAR controls.
Especially noteworthy is the feature which enables each buffer to
appear to have the performance of a multiple buffer design. The
problem of storage consistency associated with data buffer designs is
also addressed.
LFAR
The hardware controller that manages the line-fetch buffer is
called LFAR. Figure 6 depicts
this controller. LFAR is used when a request from a CP misses the L2
cache and a BSN bus operation is needed to bring data in from elsewhere
in the memory hierarchy. A pair of LFAR registers, LFARA and LFARB, are
associated with each BSN port. Thus, there are two LFARA registers and
two LFARB registers on the L2 chip.
Figure 6
Because a given L2 may have a single bus operation pending at any point
in time (a restriction imposed by the BSN bus protocols), a single
buffer was deemed adequate if it could be managed efficiently. A second
buffer would have used up valuable chip real estate. Typically, a
buffer has only one corresponding address register; in this L2
design, however, a second address register was implemented to enable
concurrent fetch-miss operations and to reduce bus idle time between
successive fetch operations on the same BSN bus. The LFARA and LFARB
registers work in tandem so that while LFARB is waiting for data to
return from the BSN bus, LFARA can be loaded with the next outgoing
fetch operation. Once the buffer starts clearing out (i.e., the first
data shot has been read out to be stored into the cache), the fetch
residing in LFARA can initiate a new request to the BSN bus for
processing. By the time data return, the data from the previous fetch
operation will already have vacated the buffer.
The following describes a fetch-miss operation as handled by the
LFARA and LFARB registers. A CP fetch operation detects a miss during
its initial pipeline pass (assuming no address or resource
conflicts). The fetch address is loaded into LFARA while the victim
cache-line address is loaded into LSARA. A request is made to the BSN
for permission to broadcast a fetch command. Once the command is
broadcast, the fetch request is moved from LFARA to LFARB to await the
return of the data and to start the sequence that will load the data
into the L2 cache. Returned data are simultaneously written into the
line-fetch buffer and sent to the requesting CP. The LFARB logic
requests priority and makes a pass through the pipeline to write the
128 bytes of data from the BSN line buffer into the L2 cache. One
quadword is written, per cycle, on consecutive cycles until the entire
line is read out of the buffer and written into the cache. If this
process completes without any errors (e.g., no uncorrectable memory
errors are detected), another pass through the pipeline is made to
validate the directory entry for the new line.
The directory entry validation is performed in a separate pipeline pass
for two reasons. First, in the event that an uncorrectable error is
detected in memory during the line transfer, the recovery protocol is
to post a machine check interrupt code (MCIC) to the operating system,
which causes it to deconfigure the physical page frame. Until this
occurs, the L2 must block any further references to the corrupted
sector of the page frame by not allowing the line to be labeled as
valid in the cache. The timing of LFARB's validation pass guarantees
that the pass is not made until the last possible storage UE report has
been detected. The second reason for having the separate validation
pass is to prevent subsequent operations to the line until it is loaded
in its entirety. This is accomplished via an address comparator
associated with LFARB, which reports an address-compare match in the
subsequent operation's initial pipeline pass.
Unlike the CP FAR and the BSN controllers, LFARB is governed only by a
mode-state machine register to allow it to transition through three
possible hardware states: wait for data, cache load pass, and directory
validation pass.
The performance benefit of the second LFAR register is realized because
as soon as the cache load from the first buffer entry is underway, the
buffer is marked available to receive new fetch data, enabling a new
fetch operation to be issued to the BSN bus. With this approach, each
L2 is able to achieve concurrent fetch-miss operations with only one
data buffer.
As in other controllers in the design, each LFAR has its own address
comparator logic for serializing operations that are potentially in
conflict with operations currently residing in LFAR. These address
comparators serve one basic purpose: They avoid problems relating to
data integrity. However, they can easily create deadlock problems if
not used carefully. For normal situations, a partial address-compare
range comprising the bits used for selecting the directory row (or
congruence class address) is sufficient to achieve the desired effect.
Although a compare based on a subset of the full line address range
results in a compare match overindication, the increase in queueing
times caused by it is slight and therefore has a negligible impact on
performance. Besides, a compare range based on the directory congruence
class was necessary to avoid the situation in which back-to-back fetch
misses on the same BSN bus are concurrently targeting the same
directory entry for cache-line replacement. A full line address compare
is needed to protect the recently acquired storage data from being
overlooked on a directory search for a bus snoop operation. A failure
to report an XI hit on the BSN bus will violate cache coherency rules.
LSAR
An LSAR controller is depicted in Figure 7.
The line- store buffer
corresponding to the line-fetch buffer is managed by the line-store
address register. Each time a fetch operation from a processor
misses the L2 cache, LSAR is responsible for the eviction of the
LRU targeted line from the cache to make room for the new fetch-miss
data.
Figure 7
In an arrangement analogous to the LFAR just described, there are two
LSAR registers, LSARA and LSARB, dedicated to each BSN port, sharing a
single line- store buffer. The cast-out data are held in the buffer
until they are allowed to transmit on the bus. Operationally, LSARA has
a hardware sequencer (the mode-state machine register) that removes CP
ownership of the LRU line and ensures that all possible updates to the
LRU line are completed before moving the data from the cache into the
line-store buffer. Once data are in the buffer, LSARB continues the
cast-out operation by protecting the data (via a full address compare)
until the BSN bus is available to process the main memory write-back
operation. After the shift from LSARA to LSARB, LSARA becomes available
to operate on a new cast-out operation. Just as LFAR is capable of
issuing back-to-back fetch operations on the BSN bus, so too can LSAR
issue back-to-back write-back operations to main store.
To maintain the full subset cache rule between L1 and L2, each LRU
operation requires an invalidation of CP ownership of the cache victim
(or LRU) line. In fact, the hardware sequence for invalidating and
ensuring the most recent data in the L2 cache is the same sequence used
by both the CP and BSN controllers when changing the directory state of
an address resident in the L2.
If the LRU line is "dirtied" (meaning that the data are more recent
than the main store copy), the data are moved out of the cache and into
the line-store buffer to wait until the bus is ready to accept the
memory-store operation. During this time, LSARA can start the
preparation for a new cast-out, but it will not move the new data into
the buffer until any previous cast-out data are on the bus.
Both LSAR registers have a congruence class address comparator to
prevent local CP operations from interfering with the LRU congruence
class management. This also prevents any inadvertent fetches from being
sent to the BSN bus ahead of a cast-out operation, since that would
violate cache coherency. An LSARB full address comparator is needed to
report an address match in the event that a remote L2 is requesting the
data while they are in the line-store buffer.
The cache interactions created by multiprocessors in a shared L2 system
require the ability to handle multiple fetch-miss operations even to
the same BSN bus. Because of technology constraints, only one
line-store buffer per BSN port side was possible, necessitating a
high-availability buffer design. This was accomplished by sharing a
single line-store buffer between two LSAR registers. The sequence LSARA
requires to invalidate the evicted cache line from the local CPs and to
ensure that the latest modified data, if any, are inside the cache
before moving the data to the line-store buffer can take a number of
cycles. By having an LSAR register pair, the L2 is not stalled after an
initial fetch-miss operation which ties up both an LFAR and an LSAR.
With the second LFAR/LSAR register, a second fetch-miss operation can
be started while the initial fetch-miss operation is underway. As soon
as that completes, the next fetch operation or cast-out operation is
ready to issue a new bus request.
Cache array
The S/390 G4 L2 has a total cache capacity of 384 KB per chip.
This is constructed from four physical arrays, each containing 96 KB of
data and providing eight bytes per access cycle. Since the L2 chip must
provide 16 bytes per cycle per operation, two physical arrays are
accessed in parallel to provide the necessary data rate.
Cache accesses that require more than 16 bytes (many accesses are for
128-byte lines) alternate between pairs of physical arrays in
successive cycles. Thus, any given physical array is busy only in
alternate cycles for multicycle operations. The intermediate cycles are
therefore available for use by another operation. This is termed
"interleaving," and each pair of physical arrays is referred to as
a "cache interleave."
This type of two-way interleaving allows for two simultaneous cache
accesses by two independent storage operations. Interleaved operations
may be any mixture of fetch or store operations, of any length. If one
cache access is already in progress, a second access never has to wait
more than one cycle to find the array containing its starting address
available for use. In situations where both interleaves are busy,
additional storage operations must wait for one of the active
operations to complete before access to the cache array is granted.
Each cache interleave has an independent controller that controls all
aspects of cache-array access, including address increment and
interleave availability notification. For multiple-cycle accesses,
addresses and control information are passed back and forth between the
interleave controllers on each successive cycle.
Each physical cache array serves both BSN buses. Half of the array
addresses are dedicated to one BSN bus, and the other half to the other
BSN bus. This restriction exists because of the structure of the cache
directories, which is dictated by directory access-time requirements
for BSN snoop operations.
The four physical cache arrays are manipulated to appear as two logical
arrays (interleaves) with 1024 rows of six compartments each, with 128
bits per compartment.
Cache-array writes may update either 64 or all 128 bits of a
compartment to accommodate doubleword and quadword stores from a CP. To
store less than a doubleword, the CP first performs a byte merge into a
doubleword in the L1 cache, then transfers the entire updated
doubleword to the L2 cache.
Figure 8 illustrates the
complete dataflow, with cache arrays and including buffers and
cross-point switches used for accessing the cache. This structure of
buffers and cross-point switches is designed to maximize system
throughput by allowing multiple simultaneous data transfers for
different requests.
Figure 8
At the top of the figure, inputs from each of the five bidirectional
data buses are shown. At the bottom, outputs are shown to each of these
same five bidirectional buses. Each bus may be in either drive or
receive mode at any given time, so up to five external data transfers
may occur simultaneously.
All data-write paths include a buffer which is used to hold data until
the needed cache interleave becomes available for writing. Buffers are
needed on the CP interfaces because the CPs are allowed to send a store
at any time (provided that the store data stack is not full), and it
may be necessary to wait for the cache interleave to complete another
operation before the data can be written to the cache. Buffers are
needed on the BSN interfaces to allow multiple operations to be active
simultaneously. Since the S/390 G4 L2 does not stall waiting for
outstanding BSN bus data requests, it is possible that returning data
will encounter a busy cache interleave, necessitating the buffer.
All data written to cache must be accompanied by ECC checking bits. The
CP stores data with the appropriate ECC check bits already supplied.
Data from the BSN bus arrive with parity and are stored with ECC bits
generated by the ECC stations (shown).
Data-read paths include buffers for data destined for the BSN bus but
not for the CPs. The BSN path requires buffers because when data are
being readied for cast-out to the BSN bus, the BUSRR may not yet have
been granted priority to send data onto the bus. The fetch-alert
response on the CP interface is used to notify the CP in advance that
data are about to be returned, blocking the CP from sending any new
stores on the BIDI interface, so data that are ready can always be sent
immediately to the CP and no buffering is needed.
All data from cache are first checked (and corrected if necessary) by
the ECC correction stations (shown), since both the CP and BSN expect
to receive data with parity, not ECC.
The seven independent cross-point switches shown in the figure are a
very important feature for maintaining performance in the S/390 G4
system SMP environment. These switches operate independently for each
CP and BSN port and for each cache array, allowing up to five
simultaneous transfers on the five L2 cache chip data ports. Data do
not pass through one common bus, which would have the effect of
limiting the L2 to one data transfer at a time. Instead, each port is
capable of operating independently of the others. Each CP port is
capable of receiving data directly from either cache interleave or
either BSN bus, each BSN line-store buffer is capable of receiving data
from either cache interleave, and each cache interleave is capable of
receiving data directly from any CP-store data stack or either BSN
line-fetch buffer. As one example, all five L2 chip ports may be
active concurrently for the following four simultaneous operations:
- Fetch from cache interleave 0 to CP0.
- Fetch from cache interleave 1 to CP1.
- Fetch from BSN 0 bus to CP2 (busies two L2 ports).
- Store from BSN 1 line-store buffer to BSN 1 bus.
Shared-cache coherency in the S/390 G4 L2 cache
The S/390 G4 system has three levels of cache hierarchy, in which
the first-level (L1) and second-level (L2) caches may contain storage
data that are more recent than those existing in the third-level (L2.5)
cache or in main memory. The S/390 G4's novel approach to tightly
coupling up to 12 microprocessors by creating a system structure
consisting of distributed shared-cache clusters led to further novelty
in coherence management for a multilevel cache hierarchy. The concept
of hierarchical ownership is introduced for the first time in S/390
with the G4 system.
The cache structure for the system consists of store-through L1 caches
located on each of the CP chips, shared store-in L2 caches located on
separate L2 chips, and store-through L2.5 caches located on each of the
four logical BSN buses. Essentially, the L2.5 operates as a main store
cache for frequently accessed, shared, read-only data. The L2 caches
are supersets of the L1 caches that are part of the same cluster; i.e.,
if a line of data exists in any of the three L1 caches that are in the
cluster, it must also exist in the L2 cache in the same cluster. The
reverse is not true, in that a line of data may exist in an L2 cache
without existing in any of the L1 caches in the same cluster. However,
there is an exception to this subset rule. The storage address range
where nonupdatable millicode is kept can be in the L1 while not in the
L2. This was done to prevent certain deadlocks on the BSN bus from
occurring [10]. There are no superset or
subset rules between the L2
and the L2.5 caches, since the L2.5 can never hold data that are more
recent than the copy in either the L2 caches or main store.
Coherency is maintained through the use of directory states that are
defined as follows for the first two levels of caches. For L1 caches,
three directory states are defined: invalid, read-only, and exclusive.
The read-only and exclusive states simply tell the CP whether or not
the data it has in its L1 can be changed. If the data are in read-only
state, a request must be made to the L2 to elevate the state from
read-only to exclusive in order to process a store.
For the L2 caches, the following directory states are defined:
invalid; read-only to CP(s), MC = 1; read-only to CP(s), MC =
0; and exclusive to a CP. The "MC" in this list refers to a
multicopy bit which is used to determine whether the line exists in
other shared L2 clusters. A value of 0 indicates that it does not,
while a value of 1 indicates that it might.
The L2 directory state is encoded in a three-bit "CPID" field that
is part of the directory tag for each cache slot. Since the MC bit is
merged into the CPID field, only two bits are used to identify the CP
ownership state.
Note that there are unique L2 directory states to keep track of which
CP owns a line exclusive, but there are no unique L2 directory states
to keep track of which CP or CPs own a line read-only. This was done to
allow the limited directory physical space to be used for ECC bits to
better protect the directory contents and to reduce design complexity.
There is very little resulting loss in system performance.
Cache coherency is primarily managed by each L2 in the system. In this
scheme, the L2 simply tells the CP how data it is fetching should be
held (read-only or exclusive) in the L1 directory, and also when to
invalidate resident data because of another CP's exclusive fetch for
the same address or an LRU situation in the L2. There are three
compelling reasons for having the coherency management situated in the
L2: 1) It simplifies the L1 function; 2) it eliminates L1 directory
resource conflict due to bus snoop operations; and 3) it allows the L2
to efficiently manage data in the system. By shielding the L1 from bus
snoops, the design avoided having to allow concurrent directory lookups
in the L1. In order for the L2 to successfully shield L1 from bus
snoops, the L2 must manage the data in its attached L1 caches as a
subset of the L2 cache.
With the S/390 G4's system of distributed shared L2 cache clusters,
read-only data can be found in one or more of the L2 clusters when the
MC status bit is active. When the bit is inactive, the L2 cluster has
sole ownership of the data. This MC concept is widely used in bus-based
SMP designs, especially in MESI (modified, exclusive, shared,
invalidate) schemes. However, because the S/390 G4 system has a
multiprocessor node on the system bus, as opposed to a single
microprocessor or a private L2, the MC concept and the ownership
concept for a shared cache were combined to form a new hierarchical
ownership concept applicable only to this type of system structure.
An example demonstrates the advantage of hierarchical ownership: In a
bus-based SMP design where each connecting node is a private L2,
modified (or "dirtied") data can exist in the L1 and its associated
L2 cache. If a CP across the BSN bus requires access to the same data,
a data transfer on the bus results, and the data end up being in both
L2 caches in a read-only state with the MC bit active. If the CP now
wishes to make a modification, a second bus operation is needed to
invalidate all multiple copies of the data. On the S/390 G4 structure,
where there are multiple CPs in a shared L2 node, if the offending CP
is on the same node as the processor that owns the modified data, the
fetch operation and the subsequent data transfer are processed entirely
within the shared- cache node without requiring the BSN bus.
Furthermore, if the offending CP wishes to make a modification, the L2
simply issues an invalidate command to the victim CP, again without
requiring the BSN bus. During this entire sequence of events, the MC
bit within the L2 remains a 0 while the CPID changes, but only to
reflect the ownership changes from exclusive to read-only and back to
exclusive states. Obviously, the S/390 G4 structure does not
eliminate all CP-to-CP data transfers, but it does reduce the bus
traffic and lessen bus queueing, improving system performance.
The L2 chip is also responsible for maintaining strict coherency for
both L1 and L2 caches. By strict coherency, it is meant that a CP is
allowed to store into a line only if it exists in an exclusive state in
its L1 directory and a copy does not exist in any other L1 in the
system or in an L2 in any other cluster. Directory states for both
levels of caches may have to be updated. This can be accomplished via
commands issued by CPs within the cluster or via commands broadcast
over the BSN bus from other clusters. For the first type, the CP
controller is responsible for making a series of pipeline passes to
update the directory states, while for the second type the BSNAR is
responsible for making the pipeline passes. Updating of the L1
directory states is done by issuing an XI command to the affected
CP(s). Note that for lines that are in a read-only state in the L2
directory, it is not known which CPs, if any, currently own a copy of
the line, so XI commands are sent to all three CPs in the cluster.
Also note that one advantage of making the L2 chip responsible for both
the L1 and L2 directory states is that some of the BSN bus activity is
shielded from the CP chips, reducing the number of L1 directory
searches that have to be performed.
One interesting case worth mentioning is the case in which a line
currently exists in the L2 in a read-only, MC =
1, unchanged state and a CP within the cluster makes a
request to own the line exclusively. Prior to updating the L1 and L2
directory states within the cluster, the CP controller must first load
the BUSRR with a line invalidate command to be broadcast on
the BSN bus to all other L2 clusters in the system. This forces the
other clusters to update their L1 and L2 directory states for this line
to invalid. Once the CP controller is notified that the line
invalidate command is broadcast on the BSN bus, it then proceeds
with pipeline passes to update the L1 and L2 directory states within
the cluster.
Interlocks and contention management
In a nonblocking switch design such as the S/390 G4 shared L2,
where multiple concurrent operations are allowed for improved system
throughput, special care must be taken to maintain data consistency.
Data integrity is compromised when operations to the same storage data
are allowed to overrun, resulting in misplacement of true data and also
bad ownership assignments. The S/390 G4 L2 avoids this problem by
employing a series of varied address comparators that are observed by
each operation as it begins processing but before it can complete.
Specifically, these address compares protect against concurrent
conflicting data accesses by multiple requestors. And they protect data
in transit between L2 clusters and between cache and main memory.
Descriptions of the different address-compare interlocks are listed
below. The first section lists the compares observed by the CFAR
controller as a request starts up. The second section lists the
compares observed by the BSN controller.
Interlocks for CFAR
requests
When an L2 receives a fetch request from a local CP, the
"valid" bit for that CP's CFAR becomes active immediately, but
address conflict must be checked before processing completes. A
distinction must be made between a CFAR request which has a conflict
and one which has no conflict. The CFAR "valid" tag bit is not
sufficient, since it has to be active in both cases, so a special tag
called "pending" was created. A request becomes "pending" after
it has made an initial directory search pass through the pipeline with
no address conflict; i.e., no other requestor is active with the same
address. Once a request is "pending," it can proceed safely to
completion, as the "pending" tag will block new requests from
accessing the same address while it remains active. The tag is reset
when the CFAR request is processed.
Different types of address compares observed by CFAR when its request
begins are the following:
- Other CFAR register compares. Each CFAR has a "pending"
bit, which indicates that it is valid for compares. If a fetch request
sees no compares against other CFARs, the requestor's pending bit is
turned on, making this request valid for compares done by other CFARs
and effectively locking out other CFAR requests to the same congruence
class. The CFAR compare protects against conflicts caused by two CPs
attempting to fetch the same line or attempting to fetch lines in the
same congruence class. This check avoids the situation in which two CPs
attempting to fetch the same line could both see the same directory
status (for example, read-only), resulting in an attempt by
each to update the line (i.e., trying to obtain exclusive
ownership). These types of situations would cause unpredictable
directory results.
- Line-fetch address register (LFAR) compares. This is done to
prevent the current request from fetching a line from the same
congruence class as a line already being fetched by another CP, thus
accessing the same directory and LRU information and potentially
overlaying the results of the first request. This check is necessary,
since the CFAR for the first request may be reset before the directory
update is complete. This is also done to prevent a situation in which
two CPs are attempting to fetch the same address which missed the L2.
There is a window condition, where the data for the first fetch-miss
have returned and are in the process of being loaded into the cache,
but the directory entry has not yet been validated. Without the LFAR
compare check, the second CP's fetch would detect a directory miss and
a new fetch for the same data would be sent out on the BSN bus,
resulting in the L2 having two cache slots for the same storage address
with potentially different CP ownership.
- Line-store address register (LSAR) compares. This compare
protects against the case in which the current fetch request is for a
line that is being LRUed or cast out of the L2.
- BSN address register (BSNAR) compares. This is done to prevent
the current fetch request from attempting to fetch data that are
currently being requested by a CP on a remote cluster. To cover the
reverse situation, where a CFAR is in the midst of acquiring ownership
of some data residing in the L2, any new remote CP request must be held
off until the local fetch operation is processed. This interlock is
accomplished by having each CFAR maintain another "pending" bit
called "BSN pending," which is turned on if no compare is detected
against a BSNAR. This makes the CFAR valid for compare for subsequent
BSNAR requests.
- Store-stack compares [8]. These are
done to ensure that any
outstanding stores to a line are complete before a fetch request for
that line is processed, a requirement for maintaining data integrity.
Since the store-stack compare is done on a subset of the line address
bit range, compares may be indicated when the store is not really to
the same line. For this reason, all checking of store-stack compares is
gated with a check of the directory hit results. If a CP does not own
the line exclusive, it cannot update it. If the line is held exclusive
by the requesting CP, compares are checked against the requestor's
store stack. If a CP other than the requestor owns the line exclusive,
a compare is done against that CP's store stack.
Interlocks for BSNAR
requests
The BSN controller is continually "snooping" the BSN bus to
determine whether commands being broadcast require action, whether
casting out changed data or invalidating old data. When a command is
detected, a directory search, using the address that was broadcast on
the BSN bus, is initiated. This is done to determine whether the line
of data resides in the L2 cache.
In parallel with the directory search, two address compares are done to
protect against cases in which the data exist in either the line-fetch
or line-store buffer but not in the cache. These two compares are
referred to as BIF compares, since the address to which the comparison
is made resides in the BIF. These are done using the entire line
address bit range.
- An LFAR BIF compare detects cases where the data are in the
line-fetch buffer waiting to be loaded into the L2 cache. If a compare
is detected, the BSN controller signals the BSN chip that this L2 has a
copy of the line and waits until the LFAR has completed loading the
data and updating the cache. Once this occurs, it proceeds normally,
i.e., as if a directory hit had been detected on the original directory
search.
- An LSAR BIF compare protects against cases where the line of
data resides in the line-store buffer waiting to be broadcast on the
BSN bus. If a compare is detected, the BSN controller signals the BSN
chip that this L2 has a copy of the line and waits for LSAR to complete
its processing of the LRU operation. Assuming that the line was changed
in the L2 cache, the data should reside in the line-store buffer at
this point, so the BSN controller broadcasts an XI cast-out command on
the BSN bus using the data in the line- store buffer, and cancels the
line-store command that was loaded into the BUSRR (bus request
register) as part of the LSAR LRU operation. If the line was not
changed in the L2 cache, LSAR would have completed the LRU operation by
simply invalidating the directory entry. In this case, the BSN
controller resets without casting out the data, and the data must be
fetched from the L2.5 or main store.
- A BUSRR compare is performed as part of maintaining cache
coherency between clusters. When a CP controller detects that the
multicopy bit is on while doing a directory search for an exclusive
fetch-type command, it loads a line invalidate command into
the BUSRR register. This command forces other L2 chips to invalidate
their copy of the data, so that it can grant exclusivity to the
requesting CP. A complication can arise when another L2 broadcasts a
command on the BSN bus that accesses the same line of data prior to the
line invalidate command being broadcast. If the line
invalidate command is allowed to be broadcast after the other
command completes, the directory entries for these data in the
different clusters may get out of sync. To prevent this from
happening, the BSN controller performs a special BSNAR versus BUSRR
compare when processing a command it has received from the BSN bus
whenever it reaches a state that causes it to update the local L2
directory state. If a match is detected and the BUSRR register contains
a line invalidate command, the CP controller is notified to
restart the operation from the beginning to see the new L2 directory
state and then to take the appropriate course of action to complete the
CP request.
Aside from these address-compare checks, when BSNAR goes through
the pipeline in its initial pass, it checks for conflicts against
pending CP operations. When a CP operation which will result in data
returned from the L2 cache is in progress, the BSNAR request must be
held up until the new directory state has been updated. This is to
ensure that the proper invalidation is sent to the CP which actually
owns the data in question. Otherwise a coherency problem will result.
The method by which this interlock is accomplished is described in the
previous section.
Conclusions
The S/390 G4 shared L2 cache design demonstrates the feasibility
and advantages of shared-cache design. It is also evidence that it is
possible to create a hybrid design which carries most of the advantages
of fully shared cache structures while enabling the use of low-cost
system bus topologies. While obviously not as optimal as a true fully
shared cache, the shared L2 cache cluster approach provides an
attractive low-cost, high-performance alternative. The G4 shared L2
allowed the S/390 design team to maximize reuse of existing
componentry without compromising the performance of the S/390 G4
microprocessor. The result is an S/390 G4 CMOS system which matches or
exceeds ES/9000 bipolar mainframe system performance at a fraction of
the cost.
The basic concepts of this shared L2 cache, most of which were
described in this paper, are expected to be capable of being extended
to provide greater cache efficiencies and sharing capabilities for
future development efforts. For example, the cross-point switches,
cache interleaving, data ownership hierarchy, and pipeline arbitration
mechanisms can easily be extended to support a larger number of
microprocessors in a given cluster. This, combined with expected
improvements in CMOS density, can lead to even larger SMP systems or
simpler, more powerful SMPs with fewer components. The S/390 L2 cache
design team is considering several of these alternatives as we continue
to increase S/390 system performance via high-performance shared-cache
designs.
Acknowledgments
The successful implementation of this shared L2 cache was in every
sense a team effort. The authors wish to thank the additional members
of the S/390 L2 logic and verification team: Michael Fee, Carl Ford,
Cara Hanson, Kevin Kark, Edward Kaminski, T. C. Lo, Patrick
Meaney, A. Rick Seigler, William Shen, Gary Van Huben, and George
Wellwood; the members of the S/390 L2 chip integration and test team:
William Scarpero, Frank Malgioglio, Adrian Zuckerman, Roy Wood, and Tom
Foote; and the S/390 L2 custom SRAM designers led by William Dachtera.
*Trademark or registered trademark of International Business
Machines Corporation.
¹For an example of independent
research confirming the concept of
shared-cache clusters, see B. A. Nayfeh, K. Olukotun, and J.
P. Singh, "The Impact of Shared Cache Clustering in Small-Scale
Shared-Memory Multiprocessors," Proceedings of the Second
International Symposium on High Performance Computer Architecture,
San Jose, CA, 1996, pp. 74-84.